New features in version 2.12.6109.0

Engineering units

In previous versions of VS EtherCAT Studio to define the engineering unit in the signals users should set similar parameters for each signal. In VS EtherCAT Studio new version users define the engineering unit only once and can select it from the list to apply to other signals.

Users can add a new engineering unit, edit or remove the existing ones. In case of editing of existing engineering unit all the changes are reflected to all signals where this engineering unit is used and during the saving appears the corresponding message.

SCI files

The new version of VS EtherCAT Studio allows to load to the Slave library not only ESI files but also SCI files.

SCI - Slave Configuration Information, contains a definite configuration for an EtherCAT Slave on the basis of the setting parameters of the device description file (ESI, EtherCAT Slave Information).

The user can save the set Slave configuration in the Slave library with the aid of SCI file and apply this configuration to other Slaves just selecting the file from the library.

Import ENI

The new version of VS EtherCAT Studio gives an opportunity to import slave configuration (process data and init commands) from ENI file.

Ready to try our VS EtherCAT Studio?